– 2 part adhesive
– Quick cure
– Maximum temperature 100°C
– Typical tube will stick 25 studs
Fitting Instructions
– To ensure that the accelerometer gives optimum performance it is important that care is taken when mounting the stud and accelerometer by following the instructions below:-
– Select a mounting position, in any plane, as close as possible to the vibration source
– Prepare a flat, smooth, unpainted surface larger than the base of the accelerometer
– Thoroughly clean the surface and the base of the glue stud with solvent
– Dispense required amount of Loctite Metal Adhesive Set onto a suitable tray. Mix thoroughly to an even colour. This should take no more than 1 – 2 minutes. Apply adhesive to the base of the stud and fit to the prepared surface. The adhesive will begin to set after a few minutes, but allow 1 hour for a full strength bond
– Before fitting the accelerometer to the stud, smear grease onto the mating surfaces to ensure good coupling to the accelerometer
– Fit the accelerometer to the stud and lightly tighten
– Loop the cable and cleat to the accelerometer body, then cleat the cable to a surface to minimise movement