Date:May 10, 2012

2 Pin MS Connector

HS-100i Series

IECEx-2Pin-TE

100mV/g Industrial Accelerometer

Typical Applications

For offline applications using commercially available intrinsically safe data collectors and online monitoring systems in the fields of Mining, Offshore, Petrochemical, Gas.

Protecting…

Fans, Motors, Pumps, Compressors, Centrifuges, Conveyers, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, HVAC, Spindles, Machine Tooling, Process Equipment and many more.

Technical Performance

Mounted Base Resonance
Sensitivity
Frequency Response
Isolation
Measurement Range
Transverse Sensitivity

22 kHz (nominal)
100 mV/g ±10% Nominal 80 Hz at 22 ºC
2 Hz to 10 kHz ±5 %
0.8 Hz to 15 kHz ±3 dB
Base isolated
±80 g
Less than 5%

 

Electrical

Electrical Noise
Current Range
Bias Voltage
Settling Time
Output Impedance
Case Isolation

0.1 mg max
0.5 mA to 8 mA
10 – 12 Volts DC
2 seconds
200 Ohms max.
>10 Ohms at 500 Volts

 

Environmental

Certified Temperature Range
Sensor Temperature Range
Sealing
Maximum Shock
Emissions
Immunity

Ex ia IIC T6 Ga (-55°C < Ta < +60°C) (Gas)
Ex ia IIIC T80°C IP65 Da (-55ºC < Ta < +60ºC) (Dust)
Ex ia IIC T4 Ga (-55°C < Ta < +110°C) (Gas)*
Ex ia IIIC T130°C IP65 Da (-55°C < Ta < +110°C) (Dust)* Ex ia I Ma (-55°C < Ta < +110°C) (Mining)
*On request – consult Sales Office
-55 to 140°C
IP67
5000 g
EN61000-6-4:2001
EN61000-6-2:1999

 

Mechanical

Case Material
Sensing Element/Construction
Mounting Torque
Weight
Maximum Cable length
Mating Connector
Mounting Threads
Options

Stainless Steel
PZT/Compression
8 Nm
110 gms (nom)
See System drawing
HS -AA004
See ‘How to order’ table
Integral cable, various connector assemblies,
other sensitivities

Intrinsically Safe Requirements

Maximum Cable Length

See System Drawing
M06-003-B (Armoured)
M06-004-B (PUR)
M06-005-B (Silicone)

Certificate details: Group I

IECEx BAS07.0037X
Baseefa07ATEX0149X
EI M1
Ex ia I Ma
(-55ºC < Ta < +110ºC)

Certificate details: Group II

IECEx BAS07.0035X
Baseefa07ATEX0144X
EII 1GD
Ex ia IIC T4 Ga
Ex ia IIIC T130ºC IP65 Da
(-55ºC < Ta < +110ºC)

Certificate details: Group II

IECEx BAS07.0035X
Baseefa07ATEX0144X
EII 1GD
Ex ia IIC T6 Ga
Ex ia IIIC T80ºC IP65 Da
(-55ºC < Ta < +60ºC)

Accelerometer System Certificate

Baseefa07Y0145
Ex ia IIC T6 (-55°C < Ta < +60°C)
Ex ia IIC T4 (-55ºC < Ta < +110ºC)
On request – consult Sales Office

System Connections

Drawing M06-003-B (Armoured)
Drawing M06-004-B (PUR)
Drawing M06-005-B (Silicone)

Terminal Parameters

Ui = 28V, Ii = 93mA, Pi = 0.65W

500V Isolation

Units Will Pass A 500V Isolation Test

Barrier

1 x Pepperl + Fuchs Galvanic Isolator
KFD2-VR4-Ex1.26 (BAS02ATEX7206)
sheet 1 of M06-003-B, M06-004-B and M06-005-B.

1 x MTL Zener Barrier MTL7728 (BAS01ATEX7217)
or Pepperl + Fuchs Zener Barrier
Z728 (BAS01ATEX7005) or any other barrier that
conforms to note 2 of sheet 2 of M06-003-B,
M06-004-B and M06-005-B.

Notes:

Special conditions of safe use for Group II dust. The free end of the cable on the integral cable version of the apparatus must be terminated in an appropriately dust-proof enclosure.

HS-100I-2-pin-ms-connector